Our Laboratories

Calibration Laboratory

In our Pressure, Balance and Volume rooms, we safeguard the reliability of your measurements with reference instruments traceable to international standards and certified engineers/specialists.

Overview

Traceable calibration for measurement reliability

Calibration is the process of establishing the relationship between the value indicated by a measuring instrument and a reference value traceable to international standards. Accurate, stable and reliable performance of medical and industrial measuring instruments is a fundamental requirement for correct diagnosis, safe treatment and quality production.

Operating since 1997, Dijital Teknoloji Servisi (DTS) works independently of brand and model, with a nationwide on-site service approach. Our calibration laboratory is structured into three separate rooms: Pressure, Balance and Volume.

  • Reference instruments traceable to international standards
  • Certified engineers and specialist staff
  • Brand- and model-independent service
  • Nationwide, on-site application on request
Scope

Three laboratory rooms, a defined scope

Each room operates with reference instruments and methods specific to its own measured quantity.

Room 01

Pressure

Calibration of positive and negative pressure measuring devices and manometers.

  • Positive / negative pressure gauge
  • Manometer
  • Traceable pressure reference standards
Room 02

Balance

Calibration of non-automatic electronic balances; linearity and repeatability assessment.

  • Non-automatic electronic balances
  • Certified reference weights (class E/F)
  • Linearity and repeatability checks
Room 03

Volume

Volume calibration of piston pipettes using the gravimetric method.

  • Piston pipette
  • Gravimetric (weighing) based method
  • Precision balance and ambient condition control
Scope Table

Measured quantity and device types

The scope below is for general information; please contact us for the current and official scope.

Laboratory RoomMeasured QuantityDevice / Sample Type
PressurePressurePositive-negative pressure gauge · Manometer
BalanceMassNon-automatic electronic balances
VolumeVolumePiston pipette
Process

The calibration process in four steps

A transparent and traceable flow from request to certificate.

  1. 01

    Request

    You submit your device details and needs by completing the Calibration Request Form.

  2. 02

    Sample / Device Intake

    The device/sample is received, identified and checked for suitability and pre-conditions.

  3. 03

    Measurement & Calibration

    Measurements are performed with reference instruments while ambient conditions are recorded.

  4. 04

    Certificate / Report

    Results are evaluated; a calibration certificate is issued together with measurement uncertainty.

Traceability

Our reference instruments are traceable to international standards; measurement uncertainty is reported.

Expert Team

Certified engineers and specialists work according to defined methods and instructions.

Decision Rule

When a conformity statement is requested, evaluation is made per our decision rule instruction.

Would you like to request a calibration quote?

Share your device list; we will get back to you as soon as possible with scope, schedule and pricing.